Dpo4054 manual




















Does anyone have info on where the serial logging port is? I have 4 of these machines that all failed in a similar way. One I checked doesn't seem to have U bad. I have a DPO that is stuck in an endless splash screen-reboot loop. Any information on the serial console location would be appreciated! Seeing I'm not alone I signed up just to say me too. A recent change has my DPO stuck on the splash screen.

Chatted with Tektronix support today and it appears they don't know about this problem. They had no idea of what could be causing it but opened a ticket Like others found, troubleshooting information is extremely limited and most of what I found was user and service manuals. The troubleshooting guide in the SM is a joke: Does instrument display power up screen? The first time restarting I gave up and power cycled and after an hour or so it was alive.

I don't know why, but last night I powered it down. Today it's worse. I get a black for minutes during that time the fan goes from overdrive to normal, after that the splash screen displays. At least this is a work scope, and I can get a replacement.

I'll suggest someone in the lab may want to check U to see if that helps. Quote from: Jwalling on November 25, , am. Quote from: JohnPi on November 22, , am. Each occurrence of each parameter is measured and added to the statistics table.

Histicons provide a fast, dynamic view of parameters and waveshape characteristics. Parameter gates define the location for measurement on the source waveform. Deviation, Top. The easy-to-use graphical interface simplifies setup of up to two operations on each function trace, and function traces can be chained together to perform math-on-math. Measurement and Math Integration Measurement and Math Integration Trend datalog of up to 1 million measurement parameters. Display System Size Color Number of traces Display a maximum of 8 traces.

Simultaneously display channel, zoom, memory and math traces. Waveforms can be stored to any number of files limited only by the data storage media capacity. Manual calibration may be invoked if outside this temperature range. SNTP support to synchronize to precision internal clocks. Includes support for extended desktop operation with UHD x pixel resolution and split-grid capability on external monitor. Supports touch screen integration of external monitor Note: external display can not use a Fujitsu touch-screen driver.

Automatically detects and supports a variety of compatible probes Scale Factors Automatically or manually selected depending on probe used Calibration Output Default is 1kHz square wave, 1Vp-p typical , output to probe hook. Settable from Hz to 1 MHz square wave; 50 mV to 1.

Shipping Weight Optional service programs include extended warranty, upgrades, and calibration services. Active Voltage Probes ZS 1. Electro Rent. Oscilloscope MHz 2. Alltest Instruments. Axiom Test Equipment. Advanced Test Equipment Corp. Oscilloscope; Digital Phosphor, MHz, 2. Top Dog Test. RF Test Equipment Solutions. Amabile Electronic Test.

Please select the Condition of the item. Quote Cart Updated. Additional Information. No user reviews yet. Please share your experience and be the first to review this product!

Add Your Own Review. Install up to four application modules at one time into the two slots with windows in the upper right corner of the front panel and the two additional slots hidden behind the two you can see. Refer to the DPO Series Application Module Installation Instructions that came with your application module for instructions on installing and testing an application module. If you remove an application module, the features provided by the application module become unavailable.

To restore the features, turn off the oscilloscope power, reinstall the module and turn on the oscilloscope power. To change the language of the oscilloscope user interface and the front-panel button labels:. Push System repeatedly until you select. Push Language from the resulting lower-bezel menu.

Push the side-bezel button corresponding to the desired language. If you choose to use English, be sure that the plastic front-panel overlay is removed. If you choose a language other than English, place the plastic overlay for the language that you desire over the front panel to display labels in that language. Push the side-panel buttons and rotate both multipurpose knobs a and b to set the time and date values. Warm up the oscilloscope for at least. Remove all input signals probes and cables from channel inputs.

Push Utility. Push System repeatedly until you select Calibration from the resulting pop-up menu. Push Signal Path from the lower-bezel menu. Push OK Compensate Signal path from the resulting side-bezel menu. After calibration, verify that the status indicator on the lower-bezel menu displays Pass. Service personnel use the factory calibration functions to calibrate the internal voltage references of the oscilloscope using external sources. Signal Path Compensation does not include calibration to the probe tip.

Open up a Web browser and go to www. Power on the DPO Welcome to ManualMachine. We have sent a verification link to to complete your registration. Log In Sign Up. Forgot password? Enter your email address and check your inbox. Please check your email for further instructions.

Enter a new password. Warranty 4 Tektronix warrants that this product will be free from defects in materials and workmanship for a period of three 3 years from the date of shipment. Table of Contents Display Waveform Data. General Safety Summary General Safety Summary Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. Connect the probe reference lead to earth ground only. The following symbols may appear on the product:.

Environmental Considerations Environmental Considerations This section provides information about the environmental impact of the product.

Product End-of-Life Handling Observe the following guidelines when recycling an instrument or component: Equipment Recycling. Installation Installation Before Installation Unpack the oscilloscope and check that you received all items listed as standard accessories. Installation Standard Accessories cont. Describes ways to develop host-computer XX software applications that work with your oscilloscope.

Installation Optional Accessories cont. Available electronically on the Documentation Browser CD or for download from www. Cleaning Inspect the oscilloscope and probes as often as operating conditions require. To clean the exterior surface, perform the following steps: 1. Tektronix Versatile Probe Interface TekVPI These probes support two-way communication with the oscilloscope through on-screen menus and remotely through programmable support. Plain BNC interfaces These probes only pass the waveform signal to the oscilloscope.

Installation For more information on the many probes available for use with DPO oscilloscopes, refer to www. Powering On the Oscilloscope Ground the Oscilloscope and Yourself Before pushing the power switch, connect the oscilloscope to an electrically neutral reference point, such as earth ground.

Installation To connect the power cord and power on the oscilloscope:. Installation Powering Off the Oscilloscope To power off the oscilloscope and remove the power cord:. Installation Functional Check Perform this quick functional check to verify that your oscilloscope is operating correctly. Press Default Setup. Installation 5. To properly compensate your passive probe: 1. Check the shape of the displayed waveform to determine if your probe is Properly compensated Under compensated Over compensated properly compensated.

Installation Quick Tips Use the shortest possible ground lead and signal path to minimize probe-induced ringing and distortion on the measured signal. Installation Optional application module packages extend the capability of your oscilloscope. Changing the User Interface Language To change the language of the oscilloscope user interface and the front-panel button labels: 1.

Installation Changing the Date and Time To set the internal clock with the current date and time: 1. To compensate the signal path: 1. Warm up the oscilloscope for at least 20 minutes.